Construction Industry professional need to be aware fire alarm legislation

Are you Building a New Property as a Homeowner, Property Developer or Builder, Do You Need Advice About Your Fire Alarms from a Local Electrician?

If you need advice or a quote for our fire alarm services such as servicing or installation then contact Top Class Electrical Services today.

As a Masters Electricians Member, we pride ourselves on being reliable contractors who provide excellent services & information; saving you time and money.

To get in touch all 0422 653 551, email daniel@topclasselectricalservices.com.au or click here to fill out the contact form.

Master Electricians Member

There’s New Smoke Alarm Legislation You Must Be Aware of

From 1 January 2017 the development approval process for new properties will ensure that building approvals received on or after this date will bring dwellings into compliance with the new laws.

Smoke alarms in the dwelling must:

    • be photoelectric (AS 3786-2014); and
    • not also contain an ionisation sensor; and
    • be hardwired to the mains power supply with a secondary power source (i.e. battery); and
    • be interconnected with every other smoke alarm in the dwelling so all activate together.

Smoke alarms must be installed on each storey:

    • in each bedroom; and
    • in hallways which connect bedrooms and the rest of the dwelling; or
    • if there is no hallway, between the bedrooms and other parts of the storey; and
    • if there are no bedrooms on a storey at least one smoke alarm must be installed in the most likely path of travel to exit the dwelling.

Where practicable smoke alarms must be placed on the ceiling. Smoke alarms must not be placed:

    • within 300mm of a corner of a ceiling and a wall; ii) within 300mm of a light fitting;
    • within 400mm of an air-conditioning vent;
    • within 400mm of the blades of a ceiling fan.

There are special requirements for stairways, sloping ceilings, and ceilings with exposed beams. Specific requirements will be explained in the Building Fire Safety Regulation 2008.

If impractical for the prescribed location requirements to be met (e.g. may be affected by steam from shower or fumes from cooking), the owner may put the alarm at another location that will provide a warning to occupants of the dwelling.

Do you need Advice on Smoke Alarms?

For peace of mind contact Top Class Electrical Services today, call 0422 653 551, email daniel@topclasselectricalservices.com.au or click here to fill out the contact form.