As home owners you need to be aware of new fire alarm legislation

As a Property Owner, Do you Need Advice About Your Fire Alarms from a Local Electrician?

If you need advice or a quote for our fire alarm services such as servicing or installation then contact Top Class Electrical Services today.

As a Masters Electricians Member, we pride ourselves on being reliable contractors who provide excellent services & information; saving you time and money.

To get in touch all 0422 653 551, email daniel@topclasselectricalservices.com.au or click here to fill out the contact form.

Master Electricians Member

We Have Advice For Homeowner Who Need to Replacing Existing Smoke Alarms

From 1 January 2017 when replacing smoke alarms, they must be of a photoelectric type which complies with Australian Standard (AS) 3786-2014.

What do Homeowner Who Are Replacing Existing Smoke Alarms Need to do?

Existing smoke alarms manufactured more than ten years ago must be replaced. (Note: Smoke alarms should have the date of manufacture stamped on them.) Smoke alarms that do not operate when tested must be replaced immediately. Existing hardwired smoke alarms that need replacement must be replaced with a hardwired smoke alarm.

What, When & Where

Smoke alarms in all dwellings must:

    • be photoelectric (AS 3786-2014); and
    • not also contain an ionisation sensor; and
    • be less than 10 years old; and
    • operate when tested; and
    • be interconnected with every other smoke alarm in the dwelling so all activate together.

Smoke alarms must be installed on each storey:

    • in each bedroom; and
    • in hallways which connect bedrooms and the rest of the dwelling; or
    • if there is no hallway, between the bedrooms and other parts of the storey; and
    • if there are no bedrooms on a storey at least one smoke alarm must be installed in the most likely path of travel to exit the dwelling.

Smoke alarms must be either hardwired or powered by a non-removable 10-year battery.

Where practicable smoke alarms must be placed on the ceiling. Smoke alarms must not be placed:

    • within 300mm of a corner of a ceiling and a wall; ii) within 300mm of a light fitting;
    • within 400mm of an air-conditioning vent;
    • within 400mm of the blades of a ceiling fan.

There are special requirements for stairways, sloping ceilings, and ceilings with exposed beams. Specific requirements will be explained in the Building Fire Safety Regulation 2008.

If impractical for the prescribed location requirements to be met (e.g. may be affected by steam from shower or fumes from cooking), the owner may put the alarm at another location that will provide a warning to occupants of the dwelling.

Do you need Advice on Smoke Alarms?

For peace of mind contact Top Class Electrical Services today, call 0422 653 551, email daniel@topclasselectricalservices.com.au or click here to fill out the contact form.